Viessmann Boiler: One-time DHW heating outside the time program
One-time DHW heating outside the time program on a Viessmann boiler: At least one heating circuit must not be in Standby mode. Party mode is used to force DHW heating once. Turn Party mode off afterwards so central heating does not run at standard temperature by accident.
Applies to: DHW heating
How to fix one-time dhw heating outside the time program: step by step
- Make sure at least one heating circuit is not in Standby mode.
- Open the extended menu and select Heating.
- Select the heating circuit if needed.
- Select Party mode.
- Set Party mode to OFF after the DHW heating is done.
If the unit shows an error code, look it up: Viessmann Boiler codes
More settings shortcuts tips for boiler
Source: Vitotrol 300A operating instructions, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.