Viessmann Boiler: Set maximum heating output
Set maximum heating output on a Viessmann boiler: Limits heating output through the modulation range. The upper limit is also set by the boiler coding card.
Applies to: Vitocrossal 300 CU3A heating output limit
How to fix set maximum heating output: step by step
- Press OK and the second button together for about 4 seconds (button symbol not legible in source).
- Select "Service functions".
- Select "Max. output".
- Select "Change?" then "Yes". A value flashes (e.g. 85), which equals 100% of rated output in the delivered condition.
- Set the required value.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
More settings shortcuts tips for boiler
Source: Viessmann Vitocrossal 300 CU3A 26 to 199 Service Instructions, p. 19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.