Viessmann Boiler: Setting central heating time phases
Setting central heating time phases on a Viessmann boiler: Time phases are set per part of the week or per day. A phase is removed by making its end time equal its start time.
Applies to: Vitotronic 300-K
How to fix setting central heating time phases: step by step
- Open the extended menu and select Heating.
- Select the heating circuit if needed.
- Select Heating time program.
- Select part of the week or a single day.
- Select the time phase.
- Set the start and end times.
- Press the exit key to leave the menu.
- To cancel a setting early, keep pressing the key until the required display appears.
- To delete a phase, set its end time equal to its start time; the display shows '- - : - -'.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitotronic 200
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Vitotronic 300-K
MW1SVitotronic 300-K, type MW2B
More settings shortcuts tips for boiler
Source: Vitotronic 200 and 300-K Operating Instructions, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.