Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Start-up, inspection and maintenance procedure index

Updated · by Aurora Star Tech Inc.

Start-up, inspection and maintenance procedure index on a Viessmann boiler: Index of the 23 start-up, inspection and maintenance steps. Each step is marked S (start-up), I (inspection) or M (maintenance). The marker columns are not clear in this extract, so the marks are not listed here. Check the full page 56 layout for the exact assignments.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W WB1B start-up, inspection and maintenance

How to fix start-up, inspection and maintenance procedure index: step by step

  1. Fill and vent the heating system.
  2. Check power supply connection.
  3. Select appropriate gas type.
  4. Measure static pressure and running pressure.
  5. Learn how the Vitodens 100-W boiler operates.
  6. Run relay tests (burner tests).
  7. Perform high altitude testing.
  8. Set maximum input.
  9. Clock the natural gas meter.
  10. Check all primary and secondary circuit connections for leaks.
  11. Perform combustion analysis.
  12. Check venting system for leaks (circular air gap measurement, sealed combustion coaxial vent only).
  13. Remove front panel.
  14. Remove burner.
  15. Check burner gasket and cylinder assembly for damage.
  16. Check and adjust ignition and ionization electrodes.
  17. Check condensate drain and clean siphon (P-trap).
  18. Check neutralization unit (if applicable).
  19. Clean combustion chamber and heat exchanger surfaces.
  20. Check diaphragm expansion tank and system pressure.
  21. Check functioning of safety valves.
  22. Check gas pipes and fittings for leaks.
  23. Reinstall burner.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Viessmann Vitodens 100-W WB1B installation and service manual, p. 56. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair