Viessmann Boiler: Control unit power supply connection
Control unit power supply connection on a Viessmann boiler: Power input to the control unit. The control must be grounded and the line, neutral and ground must not be swapped.
Applies to: Vitotronic 100 GC1, 120 VAC 1-phase
How to fix control unit power supply connection: step by step
- Make sure the main supply to the control has overcurrent protection rated at most 15 A and a 2-pole disconnect.
- Confirm the line, neutral and ground conductors are not interchanged.
- Connect the power supply wire to terminals 11, N and G on the DIN rail in the connection enclosure.
- Ground the control.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitotronic 100 GC1 / Vitotronic 300-K MW1S installation and service instructions, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.