Viessmann Boiler: Dismantle the burner
Dismantle the burner on a Viessmann boiler: Removing the upper burner section and then the burner tube assembly. A lifting device is needed for the burner.
Applies to: CA3B 2.5 to 6.0
How to fix dismantle the burner: step by step
- Close the gas shut-off valve and make sure the boiler is cold.
- Disconnect the burner gas line.
- Disconnect the connectors from the burner control unit.
- Pull off the ignition electrode connectors.
- Remove the 2 screws on the ignition electrode block and lift the block off.
- Remove the 6 nuts around the burner mounting plate.
- Remove the upper burner section.
- Secure the lifting chains at the 3 points on the upper burner frame.
- Remove the 8 nuts from the combustion chamber cover plate.
- Lift out the mounting plate with the burner tube using a lifting device.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CA3B 2.5 BoilerCA3B 3.0 BoilerCA3B 3.5 BoilerCA3B 4.0 BoilerCA3B 5.0 BoilerCA3B 6.0 BoilerCA3B Series 2.5CA3B Series 3.0CA3B Series 3.5CA3B Series 4.0CA3B Series 5.0CA3B Series 6.0Vitocrossal 300 CA3B 2.5Vitocrossal 300 CA3B 3.5Vitocrossal 300 CA3B 4.0Vitocrossal 300 CA3B 5.0Vitocrossal 300 CA3B 6.0Vitocrossal 300 CA3B Series 2.5Vitocrossal 300 CA3B Series 3.0Vitocrossal 300 CA3B Series 3.5Vitocrossal 300 CA3B Series 4.0Vitocrossal 300 CA3B Series 5.0Vitocrossal 300 CA3B Series 6.0
Source: Vitocrossal 300 CA3B Series 2.5 to 6.0 Service Instructions, p. 70-71. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.