Viessmann Error Code EEE: Data record error or out-of-range parameter (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code EEE on a boiler means: Data record error or out-of-range parameter. It is also called Viessmann diagnostic code EEE.

High severityBoilerVitotron 100 VLN2

Homeowner? What Viessmann code EEE means for you

Call a technician Your boiler is reporting: Data record error or out-of-range parameter. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EEE mean?

The control panel shows EEE. This points to a data record error, a parameter outside its allowed range, or a failed temperature sensor.

Applies to: Vitotron 100 VLN2 wall-mounted electric boiler

Common causes of Viessmann code EEE

  • Data record error
  • Parameter out of range
  • Failed temperature sensor
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EEE

VLN2 04VLN2 06VLN2 08VLN2 12VLN2 14.4

Other Viessmann Boiler codes

CodeMeaning
EC 67 or 195Parameter fault at calibration
EDIgnition relay fault
ED 191Internal burner control fault
EEInternal feedback error, gas safety valves
E e0Viessmann 2-wire BUS communication module cable break
EE 132Flame signal missing or weak at burner start
EFInternal feedback error, gas safety valves
EF 138Flame lost during safety time
Ext. controlHeating program changed by external control
External Hook-upOperating program changed by external device
FFault shutdown
F.5Sensor circuit fault at plug 33 (X6)

All Viessmann Boiler error codes →

Viessmann code EEE: homeowner questions

What does Viessmann code EEE mean?

Data record error or out-of-range parameter. The control panel shows EEE. This points to a data record error, a parameter outside its allowed range, or a failed temperature sensor.

Is it safe to keep using my boiler with code EEE?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EEE myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EEE comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EEE near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitotron 100 VLN2 installation and service instructions, p. 12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977