Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Service interval message on the display

Updated · by Aurora Star Tech Inc.

Service interval message on the display on a Viessmann boiler: After the service limits in coding addresses 21 and 23 are reached, the red fault indicator flashes and the display shows Service with the service symbol.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA 45, 60

Common causes of service interval message on the display

  • Hours run or time interval limit set in coding 21 or 23 has been reached.

How to fix service interval message on the display: step by step

  1. Press OK to acknowledge the service message.
  2. Note: an acknowledged message that was not reset comes back on the following Monday.
  3. After the service is done, press OK and the second key together for about 4 seconds.
  4. Select Service functions, then Service reset.
  5. The hours run and time interval counters restart at 0.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977