Viessmann Boiler: Check and replace refractory ring and DHW tank burner

Updated · by Aurora Star Tech Inc.

Check and replace refractory ring and DHW tank burner on a Viessmann boiler: Inspect the burner refractory ring and the DHW tank burner assembly for damage and replace if needed. Use a calibrated torque wrench for the fasteners.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA

How to fix check and replace refractory ring and dhw tank burner: step by step

  1. Remove the electrode block and ionization electrode.
  2. Release the three retaining clips on the refractory ring and remove the ring.
  3. Remove the four Torx screws, then the DHW tank burner assembly and its assembly gasket.
  4. Fit the new DHW tank burner assembly and new gasket. Tighten to 3.3 lb.ft (4.5 Nm).
  5. Refit the refractory ring and secure with the retaining clips.
  6. Refit the electrode block and ionization electrode. Tighten to 3 lb.ft (4 Nm).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitodens 200-W B2HA 112, 150, 399, 530 Service Instructions, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.