Viessmann Boiler: No central heating
No central heating on a Viessmann boiler: Causes and checks for when the rooms get no heat.
Applies to: Vitodens 100-W B1HE/B1KE
Common causes of no central heating
- The boiler is switched off.
- Incorrect control unit settings, or central heating is not enabled.
- The DHW tank is being heated.
- No fuel supply.
- A burner fault is displayed.
- An error message is displayed.
How to fix no central heating: step by step
- Turn on the ON/OFF switch and the power supply to the system.
- Check that central heating is enabled, then check the operating program, supply temperature and time.
- Wait until the DHW tank has finished heating, or reduce the DHW draw-off rate or the set DHW temperature.
- Open the gas shut-off valve. Check with the gas supplier if needed.
- Reset the burner if a burner fault is displayed.
- Check the error message, write it down, acknowledge the fault and notify the contractor if needed.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W B1HE/B1KE operating instructions, p. 29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.