Viessmann Boiler: Connect two-stage or modulating burner

Updated · by Aurora Star Tech Inc.

Connect two-stage or modulating burner on a Viessmann boiler: Wiring for two-stage or modulating burners via the 2-stage/modulating extension.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 300 with two-stage or modulating burner

How to fix connect two-stage or modulating burner: step by step

  1. Connect the 2-stage or modulating module with its potential-free burner control output to the control unit.
  2. Use terminals T6, T7 and T8 for the two-stage burner or modulation controller signal.
  3. Insert the connector in the correct terminal and apply strain relief to the cable.
  4. Follow the boiler and extension installation instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitotronic 300 installation instructions, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.