Viessmann Boiler: Burner does not switch on (multi-boiler)
Burner does not switch on (multi-boiler) on a Viessmann boiler: Boiler is requested but the burner does not fire.
Applies to: Multi-boiler systems
Common causes of burner does not switch on (multi-boiler)
- Heating program 9 is set (its button is lit)
- Vitoair draught stabilizer defective (pressure jet burner boilers only)
- Motor-controlled flue gas damper failed (gas boilers with atmospheric burner only)
- Fault on the control unit
- No fuel: oil or LPG supply empty, or natural gas valve closed
How to fix burner does not switch on (multi-boiler): step by step
- Set the rw heating program (see page 6).
- If the Vitoair is faulty, inform the heating contractor. To run it in manual, press in rotary knob A on the motor and turn it fully beyond setting 4.
- If the flue gas damper has failed, inform the heating contractor. To run it in manual, press in rotary knob A on the motor and turn it fully beyond setting 4.
- If there is a control unit fault, consult the heating contractor. Only then turn emissions test switch S to h with the cover left open.
- Oil or LPG: check the fuel supply and reorder if needed. Natural gas: open the gas shut-off valve or contact the gas supplier.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 100, GC1 operating instructions, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.