Viessmann Boiler: Heating water and DHW connections
Heating water and DHW connections on a Viessmann boiler: Flush the heating system before connecting the boiler, especially when adding it to an existing system. Field-supplied nipples and tees are used for the DHW supply and return. The boiler must not be exposed to pressures or temperatures above the listed limits.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
How to fix heating water and dhw connections: step by step
- Thoroughly flush the heating system (especially before connecting to an existing system).
- Connect the boiler supply and return and the DHW supply and return (DS and DR) as shown.
- Use field-supplied nipples and tees for the DHW connections.
- Apply enough thread sealant (supplied) to all connections.
- Do not expose the boiler to pressures or temperatures above the listed maximums.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB installation manual, p. 20. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.