Viessmann Boiler: System Layout 1: boiler with DHW tank and one heating circuit
System Layout 1: boiler with DHW tank and one heating circuit on a Viessmann boiler: Boiler feeds a DHW storage tank and one heating circuit directly. An external boiler controller with room thermostat connection is field supplied. A pressure-activated bypass is needed if components in the heating circuit can isolate pump flow.
Applies to: B1HE 85, 120, 150, 199 with DHW storage tank
How to fix system layout 1: boiler with dhw tank and one heating circuit: step by step
- Connect the DHW tank temperature sensor or DHW temperature switch.
- Connect the outdoor temperature sensor.
- Install a pressure-activated bypass if heating circuit components can isolate pump flow.
- Check flow against the B1HE flow table and residual head curves.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 100-W B1HE/B1KE Combi Installation and Service Instructions, p. 33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.