Viessmann Boiler: Call up coding level 2
Call up coding level 2 on a Viessmann boiler: Coding level 2 gives access to all coding addresses, including those in coding level 1. Codes that are not assigned by the equipment level or by other codes are not shown.
Applies to: Vitodens 200-W B2HA 112/150/399/530
How to fix call up coding level 2: step by step
- Press OK together with the second key (its symbol is not legible in this extract) for about 4 seconds.
- Repeat the same key press for about 4 seconds.
- Wait for the 'Coding level 2' display.
- Select the coding group: General, Boiler, DHW, Solar, Heating circuit 1/2/3, or All cod. or solar.
- Select the coding address, choose the value from the table and confirm with OK.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
More access & passwords tips for boiler
Source: Vitodens 200-W B2HA 112, 150, 399, 530 Service Instructions, p. 52. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.