Viessmann Boiler: Hydrostatic pressure test before connecting power and piping

Updated · by Aurora Star Tech Inc.

Hydrostatic pressure test before connecting power and piping on a Viessmann boiler: Leak test the boiler water side before it is connected to piping or electrical supply.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA 45, 60

How to fix hydrostatic pressure test before connecting power and piping: step by step

  1. Install the safety devices first, then put a temporary cap on the ¾ in. x 2 in. nipple.
  2. Cap the supply and return connections.
  3. Connect a ½ in. garden hose to the boiler fill valve at the bottom of the boiler and fill slowly to the test pressure shown on the pressure gauge.
  4. Hold the pressure for 15 minutes and do not leave the boiler unattended.
  5. Check all joints and safety devices with a flashlight for leaks. A lower gauge reading usually means water loss. Repair all leaks.
  6. After 15 minutes, open the drain valve slowly to release pressure. Remove the caps and install the pressure relief valve in place of the ¾ in. cap.
  7. Continue installation only after the boiler passes the test.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 200-W B2HA 45, 60 installation instructions, p. 30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.