Applies to: Vitotronic 100 GC1 low water cut-off wiring

How to fix connecting low water cut-off device: step by step

  1. Disconnect power to the control and burner.
  2. Remove the jumper between terminals 12 and 15.
  3. Connect the low water cut-off as shown in the diagram.
  4. Note: aBH supplies 120 VAC power for accessories; aBÖ is the connection for external safety equipment at 120 VAC.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 100, type GC1

Source: Vitotronic 100 GC1 / 300-K MW1S installation and service instructions, p. 39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.