Viessmann Boiler: Cleaning the heating surfaces and combustion chamber
Cleaning the heating surfaces and combustion chamber on a Viessmann boiler: Do not brush the heat exchanger. Scratches cause corrosion and brushing lodges deposits between coils. Discoloration is normal and does not affect function.
Applies to: Stainless steel heat exchanger
Common causes of cleaning the heating surfaces and combustion chamber
- Sediment or debris in the coil gaps
How to fix cleaning the heating surfaces and combustion chamber: step by step
- Remove the burner assembly and reinstall it after service (see p. 50).
- Vacuum loose debris out of the combustion chamber.
- Rinse embedded sediment from the stainless steel heat exchanger with water or an approved cleaner such as Axiom Clean F Steel, following its instructions.
- Keep the refractory dry.
- If coil gaps are plugged, remove debris with the Viessmann tool (part 7858492, replacement blade 7840346) without scratching the surface.
- Flush the combustion chamber with water until it runs clear through the condensate trap.
- Clean out debris from the condensate trap and reinstall it.
- Cover electronic components with watertight material before cleaning.
- Never use a metal wire brush or powered brush.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 54. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.