Viessmann Boiler: System Layout 7: direct radiator circuit plus system-separated underfloor circuit
System Layout 7: direct radiator circuit plus system-separated underfloor circuit on a Viessmann boiler: Vitodens 200-W B2HB with a direct radiator circuit and an underfloor circuit with system separation. The boiler pump 20 supplies the radiator circuit and the plate heat exchanger.
Applies to: Vitodens 200-W B2HB
How to fix system layout 7: direct radiator circuit plus system-separated underfloor circuit: step by step
- Keep total circuit flow below the boiler maximum on page 31.
- Use a low-loss header if flow exceeds page 31 values or is unknown.
- Make sure the plate heat exchanger secondary pressure drop is less than or equal to the 3-way mixing valve pressure drop.
- Install the mixing valve accessory kit and mixing valve temperature sensor.
- Pipe the DHW circulating pump Q into the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Installation Instructions, p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.