Viessmann Boiler: There is no hot water
There is no hot water on a Viessmann boiler: No domestic hot water (DHW) is being supplied.
Applies to: Vitotrol 200A with Vitotronic control unit
Common causes of there is no hot water
- Remote control set incorrectly; DHW heating is not enabled.
- No fuel supply.
- A fault is active at the Vitotronic control unit.
How to fix there is no hot water: step by step
- Check that DHW heating has been enabled. The DHW only or central heating and DHW heating program must be selected.
- With oil or LPG, check the fuel reserves and reorder if required.
- With natural gas, open the gas shut-off valve. If needed, check with the gas supplier.
- If the fault symbol is flashing, scan and acknowledge the fault at the Vitotronic control unit.
- If needed, notify the heating contractor. Refer to the control unit operating instructions.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotrol 200A Installation, Operating and Service Instructions, p. 12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.