Viessmann Boiler: Convert from natural gas to liquid propane
Convert from natural gas to liquid propane on a Viessmann boiler: Field conversion of the gas valve and coding to liquid propane. Apply the supplied conversion labels when finished.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
How to fix convert from natural gas to liquid propane: step by step
- Set adjusting screw A at the gas valve to "2" using a 2.5 mm hex key.
- Switch ON/OFF switch 8 to ON. Slide the black control cover out to reach it.
- Enter coding level 2 and open "General".
- Set coding address 11 to 9.
- Set coding address 82 to 1 for liquid propane.
- Return to coding address 11 and set any value except 9.
- Exit coding level 2 and open the gas shut-off valve.
- Apply the supplied fuel conversion labels.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
More commissioning tips for boiler
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Service Instructions, p. 19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.