Viessmann Boiler: Checking the tank and outlet temperature sensors
Checking the tank and outlet temperature sensors on a Viessmann boiler: Resistance check of the DHW tank and outlet temperature sensors.
Applies to: Tank and outlet temperature sensors
How to fix checking the tank and outlet temperature sensors: step by step
- Check the lead and plug of the tank or outlet temperature sensor.
- Disconnect the wires from the sensor plug.
- Check the sensor resistance against the curve for the current temperature.
- If the deviation is severe (over 10%), replace the sensor.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 100-W B1HE/B1KE installation/service manual, p. 83. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.