Viessmann Boiler: Check power pump module fuse F1

Updated · by Aurora Star Tech Inc.

Check power pump module fuse F1 on a Viessmann boiler: Check the fuse on the power pump module.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Power pump module fuse F1 T6.3A

How to fix check power pump module fuse f1: step by step

  1. Switch off the main power supply. The boiler ON/OFF switch does not disconnect power to the power pump module, so the main service switch or breaker must be turned off.
  2. Flip down and remove the control unit.
  3. Remove the power pump module cover plate.
  4. Check fuse F1, T6.3A slow blow.
  5. Replacement fuses come from Viessmann in packs of 10 (Part No. 7815 580).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

WB1AWB1B

Source: Vitodens 100-W, WB1B CombiPlus Installation & Service, p. 81. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977