Roof vent height and chimney routing on a Viessmann boiler: Special vent with positive pressure has height and routing limits when passing through a roof.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Special vent systems with positive vent pressure

How to fix roof vent height and chimney routing: step by step

  1. Extend the vent at least 18 in above the highest roof penetration point and any obstruction within 18 in horizontal distance.
  2. Do not route the special vent into, through or within another vent or existing chimney.
  3. Use a masonry chimney flue only if no other appliance vents into that flue.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

More other tips for boiler

Source: Vitocrossal 200 CI2 Installation manual, p. 58. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.