Viessmann Boiler: DHW call for heat from a tank aquastat
DHW call for heat from a tank aquastat on a Viessmann boiler: With a tank temperature switch (aquastat), the boiler target is the maximum permissible value for that boiler.
Applies to: Vitodens 100-W B1HE/B1KE
How to fix dhw call for heat from a tank aquastat: step by step
- No demand from the aquastat means no frost protection.
- Demand from the aquastat calls for the target value. There is no time program for DHW, no scald protection and no increased DHW hygiene in this case.
- Maximum DHW heating duration and minimum wait before the next DHW heating still apply. Check the system configuration parameter DHW.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W B1HE/B1KE installation manual, p. 92. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.