Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Conversion to liquid propane gas (LPG)

Updated · by Aurora Star Tech Inc.

Conversion to liquid propane gas (LPG) on a Viessmann boiler: Convert the burner from natural gas to LPG using the LPG kit supplied with the burner. Escaping gas is an explosion risk, so check all fittings for leaks.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocrossal 200 CM2 186 to 311 boilers

How to fix conversion to liquid propane gas (lpg): step by step

  1. Close the gas shut-off valve.
  2. Switch off the system ON/OFF switch at the boiler control unit.
  3. Switch off the main boiler circuit breaker or power supply and prevent reconnection.
  4. Remove the boiler front cover.
  5. Undo gas supply fitting A.
  6. Disconnect compensation tubing B from the venturi tube and gas valve.
  7. Remove four 8 mm hex nuts and detach the gas valve from flange C.
  8. Remove and discard O-ring F from the gas valve.
  9. Install rubberized cork gasket E on the gas valve face.
  10. Install the LPG orifice D with the pin at the top and to the rear.
  11. Install a second rubberized cork gasket on top of the orifice.
  12. Secure gas valve, orifice and gaskets to flange C. Torque nuts diagonally to 17.7 lb-in (2.0 Nm).
  13. Secure and tighten gas supply fitting A.
  14. Reconnect compensation tubing B.
  15. Apply the partial rating plate, the NG-to-LPG-labels and the conversion label as described, and complete the conversion report.
  16. Check all gas fittings for leaks. Do not let leak spray touch electrical components.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

186246311CM2 186 burnerCM2 246 burnerCM2 311 burnerVitocrossal 200 CM2 186Vitocrossal 200 CM2 246Vitocrossal 200 CM2 311Vitocrossal 200 CM2 400Vitocrossal 200 CM2 500Vitocrossal 200 CM2 620Vitocrossal 200 CM2 620 TX

Source: Vitocrossal 200 CM2 186 to 311 Service Instructions, p. 11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair