Viessmann Boiler: System layout 2: underfloor circuit with mixing valve and system separation
System layout 2: underfloor circuit with mixing valve and system separation on a Viessmann boiler: Low-temperature underfloor heating isolated by a plate heat exchanger, with DHW production. Required where non-oxygen-barrier tubing is used.
Applies to: Vitocrossal 300 CU3A, system layout 2
How to fix system layout 2: underfloor circuit with mixing valve and system separation: step by step
- Install a plate heat exchanger for system separation.
- Use corrosion-resistant materials on the secondary side of the heat exchanger.
- Size the field-supplied pump P carefully using the boiler supply head pressure drop on page 18.
- Connect the accessory kit for the mixing valve circuit and the mixing valve temperature sensor.
- Set the DHW recirculation pump function per coding address 53.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
2635455794125160199CU3ACU3A 26CU3A 35CU3A 45CU3A 57CU3A 94CU3A 125CU3A 160CU3A 199Vitocrossal 300, type CT3
Source: Viessmann Vitocrossal 300 CU3A installation manual, p. 45. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.