Viessmann Boiler: Burner motor power supply, 240 VAC 1-phase in conduit

Updated · by Aurora Star Tech Inc.

Burner motor power supply, 240 VAC 1-phase in conduit on a Viessmann boiler: Power the burner motor from 240 VAC single phase using the factory-supplied cable and conduit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Burners with 240 VAC, 1PH supply and connection in conduit

How to fix burner motor power supply, 240 vac 1-phase in conduit: step by step

  1. Disconnect power to the burner and the boiler control.
  2. Connect 240 VAC to terminals 21, 22 and 23 on the DIN rail in the connection enclosure. Fit a fuseable disconnect according to local codes.
  3. Connect the supplied power cable to the motor terminals on the burner.
  4. Plug the cable plug into the socket on the DIN rail in the connection enclosure.
  5. Check fuse and wire gauge sizing in the burner manual.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 100, type GC1

Source: Vitotronic 100 GC1 / Vitotronic 300-K MW1S installation and service instructions, p. 51. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.