Viessmann Error Code F.1062: O2 controller and BCU measurements disagree (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F.1062 on a boiler means: O2 controller and BCU measurements disagree. It is also called Viessmann diagnostic code F.1062.

High severityBoilerVitocrossal 200 CI2

Homeowner? What Viessmann code F.1062 means for you

Call a technician Your boiler is reporting: O2 controller and BCU measurements disagree. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.1062 mean?

The burner is in a fault state because the value measured by the O2 controller does not match the comparison measurement on the burner control unit.

Applies to: Vitocrossal 200 CI2

Common causes of Viessmann code F.1062

  • Bad plug or lead on the O2 probe
  • Faulty burner control unit (BCU)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.1062

Show all 21 models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

Other Viessmann Boiler codes

CodeMeaning
F.982No heating or DHW: heating circuit 1 pump running dry
F.986Parameter plausibility check failed between burner 1 and burner 2
F.1001Burner control unit not calibrated
F.1002Burner control unit not calibrated
F.1004Reverse flow of flue gas in dry mode (CI2 1500/2000, partial load)
F.1061Faulty BCU or faulty lead from O2 probe to BCU
F0Communication fault, combustion control unit
F01 : 01Participant check display
F1Flue gas temperature limit has tripped
F1 135Maximum flue gas temperature exceeded
F2Temperature limit has tripped
F2 129Fixed high limit switch open

All Viessmann Boiler error codes →

Viessmann code F.1062: homeowner questions

What does Viessmann code F.1062 mean?

O2 controller and BCU measurements disagree. The burner is in a fault state because the value measured by the O2 controller does not match the comparison measurement on the burner control unit.

Is it safe to keep using my boiler with code F.1062?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code F.1062 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F.1062 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F.1062 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CI2 Service Instructions, p. 74. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.