Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code F1 135: Maximum flue gas temperature exceeded (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F1 135 on a boiler means: Maximum flue gas temperature exceeded. It is also called Viessmann diagnostic code F1 135.

High severityBoilerVitodens 200-W B2HA

Homeowner? What Viessmann code F1 135 means for you

Call a technician Your boiler is reporting: Maximum flue gas temperature exceeded. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F1 135 mean?

Burner in fault mode. Maximum flue gas temperature exceeded, 230°F (110°C) limit. Detailed code 135.

Applies to: Vitodens 200-W B2HA 45, 60

Common causes of Viessmann code F1 135

  • Low heating system fill level
  • Air in system
  • Circulation pump fault

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
F.1004Reverse flow of flue gas in dry mode (CI2 1500/2000, partial load)
F.1061Faulty BCU or faulty lead from O2 probe to BCU
F.1062O2 controller and BCU measurements disagree
F0Communication fault, combustion control unit
F01 : 01Participant check display
F1Flue gas temperature limit has tripped
F2Temperature limit has tripped
F2 129Fixed high limit switch open
F3Flame signal present at burner start
F3 139Flame signal present at burner start
F4Flame signal not present
F5Air pressure switch not open for burner start

All Viessmann Boiler error codes →

Viessmann code F1 135: homeowner questions

What does Viessmann code F1 135 mean?

Maximum flue gas temperature exceeded. Burner in fault mode. Maximum flue gas temperature exceeded, 230°F (110°C) limit. Detailed code 135.

Is it safe to keep using my boiler with code F1 135?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code F1 135 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F1 135 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F1 135 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977