Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code F01 : 01: Participant check display (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F01 : 01 on a boiler means: Participant check display. It is also called Viessmann diagnostic code F01 : 01.

Low severityBoilerVitotronic 300-K MW1S

Homeowner? What Viessmann code F01 : 01 means for you

Usually minor Your boiler is reporting: Participant check display. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F01 : 01 mean?

Shown during the LON participant check. The first value is the participant number and the second is the consecutive list number.

Applies to: Vitotronic 300-K, MW1S

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
F.1001Burner control unit not calibrated
F.1002Burner control unit not calibrated
F.1004Reverse flow of flue gas in dry mode (CI2 1500/2000, partial load)
F.1061Faulty BCU or faulty lead from O2 probe to BCU
F.1062O2 controller and BCU measurements disagree
F0Communication fault, combustion control unit
F1Flue gas temperature limit has tripped
F1 135Maximum flue gas temperature exceeded
F2Temperature limit has tripped
F2 129Fixed high limit switch open
F3Flame signal present at burner start
F3 139Flame signal present at burner start

All Viessmann Boiler error codes →

Viessmann code F01 : 01: homeowner questions

What does Viessmann code F01 : 01 mean?

Participant check display. Shown during the LON participant check. The first value is the participant number and the second is the consecutive list number.

Is it safe to keep using my boiler with code F01 : 01?

Usually yes. Code F01 : 01 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code F01 : 01 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F01 : 01 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F01 : 01 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitotronic 100/300-K installation and service manual, p. 76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.