Updated · by Aurora Star Tech Inc.

Viessmann CI2 399 error codes and diagnostic codes (also listed as Vitocrossal 200 CI2 399). The CI2 399 is a Viessmann boiler in the Vitocrossal 200 CI2 series.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Viessmann CI2 399 error codes list

CodeMeaningSeverity
A.48Reduced system output: condensate backup or wind influenceLow
Burner faultBurner locked outHigh
External Hook-upOperating program changed by external deviceLow
F.64Flame loss during stabilization or operating phaseLow
F.65No or insufficient flame signal at burner startHigh
F.87Water pressure too highHigh
F.99PlusBus communication errorHigh
F.343Short circuit, common return sensor (low loss header)Low
F.344Lead break, common return sensor (low loss header)Low
F.347Oxygen content fell below 0%: safety shutdownCritical
F.364Internal system faultHigh
F.365Gas fitting relay monitoring has respondedHigh
F.371Fan speed not reached, below minimum speedHigh
F.519BACnet communication error with building management systemLow
F.520Modbus communication error with building management systemLow
F.541No feedback from flue gas damperHigh
F.542Heating circuit 1 supply sensor lead break, emergency modeMedium
F.543Heating circuit 1 supply sensor short circuit, emergency modeMedium
F.575Room temperature sensor lead break, heating circuit 1Low
F.576Room temperature sensor short circuit, heating circuit 1Low
F.577Room temperature sensor for heating circuit 2 not availableLow
F.578Room temperature sensor lead break, heating circuit 2Low
F.579Room temperature sensor short circuit, heating circuit 2Low
F.580Room temperature sensor for heating circuit 3 not availableLow
F.581Room temperature sensor lead break, heating circuit 3Low
F.582Room temperature sensor short circuit, heating circuit 3Low
F.583Room temperature sensor for heating circuit 4 not availableLow
F.584Room temperature sensor lead break, heating circuit 4Low
F.585Room temperature sensor short circuit, heating circuit 4Low
F.623Heating circuit 1 return sensor lead break, emergency modeMedium
F.624Heating circuit 1 return sensor short circuit, emergency modeMedium
F.625Heating circuit 2 return sensor lead break, emergency modeMedium
F.626Heating circuit 2 return sensor short circuit, emergency modeMedium
F.627Heating circuit 3 return sensor lead break, emergency modeMedium
F.628Heating circuit 3 return sensor short circuit, emergency modeMedium
F.629Heating circuit 4 return sensor lead break, emergency modeMedium
F.630Heating circuit 4 return sensor short circuit, emergency modeMedium
F.688Communication error MZIO electronics moduleMedium
F.692Burner ventilation air supply interruptedHigh
F.694Fault in heat generator supply temperature sensorHigh
F.875Communication error with lead boilerMedium
F.882Gas outlet pressure too high (GDW3)Critical
F.883Gas valve test malfunctionHigh
F.884Gas valve test malfunction, VPS pressure not rising during fillingHigh
F.885Gas valve test faulty, valve seat V2 faultyCritical
F.886Gas valve test malfunction, VPS pressure not dropping during VPS testHigh
F.887Gas valve test faulty, valve seat V1 faultyCritical
F.888Communication error with Lambda probe controllerHigh
F.889O2 probe malfunction, cyclic probe check failedHigh
F.890O2 probe malfunction, cyclic probe check failed (flue gas and air checks)High
F.891O2 probe not ready in pre/post purgeHigh
F.892Burner fault: O2 probe malfunction, calibration failedMedium
F.893Burner fault: O2 probe malfunction, calibration failedMedium
F.894Burner fault: O2 probe malfunction, probe heatingHigh
F.895Burner fault: O2 probe malfunction, wearMedium
F.896Safety chain 1 has respondedHigh
F.897Safety chain 2 has respondedCritical
F.920MZIO function fault, digital input 1Medium
F.921MZIO function fault, digital input 2Medium
F.922MZIO function fault, digital input 3Medium
F.971Gas fitting replaced, calibration value not enteredHigh
F.982No heating or DHW: heating circuit 1 pump running dryHigh
F.986Parameter plausibility check failed between burner 1 and burner 2Medium
F.1001Burner control unit not calibratedHigh
F.1002Burner control unit not calibratedHigh
F.1004Reverse flow of flue gas in dry mode (CI2 1500/2000, partial load)High
F.1061Faulty BCU or faulty lead from O2 probe to BCUHigh
F.1062O2 controller and BCU measurements disagreeHigh
P.36Air filter contaminatedLow
Panel LockedControl panel lockedLow
ServiceService dueLow

Troubleshooting the CI2 399

All Viessmann Boiler error codes →

Homeowner help: Boiler Not Heating: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.