Viessmann Error Code F E4: Repeated undervoltage, burner shuts down (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F E4 on a boiler means: Repeated undervoltage, burner shuts down. It is also called Viessmann diagnostic code F E4.

Medium severityBoilerVitocrossal 200 CM2

Homeowner? What Viessmann code F E4 means for you

Check, then call Your boiler is reporting: Repeated undervoltage, burner shuts down. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F E4 mean?

The burner shuts down because undervoltage was detected several times.

Applies to: Vitocrossal 200 CM2 burner control unit

Common causes of Viessmann code F E4

  • Multiple detections of undervoltage
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F E4

186246311CM2 186 burnerCM2 246 burnerCM2 311 burnerVitocrossal 200 CM2 186Vitocrossal 200 CM2 246Vitocrossal 200 CM2 311Vitocrossal 200 CM2 400Vitocrossal 200 CM2 500Vitocrossal 200 CM2 620Vitocrossal 200 CM2 620 TX

Other Viessmann Boiler codes

CodeMeaning
F d0Multiple gas types selected
FD 227Boiler coding card missing (with B7)
FECoding plug defective or wrong EMV error
F E0Gas inlet valve not tight (dual fuel)
F E1Gas pressure switch 2 (GDW2) closed on pressure rise
F E2Gas pressure switch 2 (GDW2) did not close or gas shortage / valve leak
F E5Internal burner control fault, ionization input
F E7Boiler temperature sensor 2 short circuit
F E8Boiler temperature sensor 2 drift
F E9Boiler temperature sensor 2 lead break
FE 158, 159, 162 or 225Damaged or wrong boiler coding card or main PCB
F EAMain gas valve leaking (multiple gas types)

All Viessmann Boiler error codes →

Viessmann code F E4: homeowner questions

What does Viessmann code F E4 mean?

Repeated undervoltage, burner shuts down. The burner shuts down because undervoltage was detected several times.

Is it safe to keep using my boiler with code F E4?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code F E4 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F E4 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F E4 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CM2 186 to 311 Service Instructions, p. 50. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.