Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code F E1: Gas pressure switch 2 (GDW2) closed on pressure rise (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F E1 on a boiler means: Gas pressure switch 2 (GDW2) closed on pressure rise. It is also called Viessmann diagnostic code F E1.

Critical severityBoilerVitocrossal 300 CA3B Dual Fuel

Homeowner? What Viessmann code F E1 means for you

Stop and call Your boiler is reporting: Gas pressure switch 2 (GDW2) closed on pressure rise. This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F E1 mean?

Gas pressure switch 2 activates while the burner test firing valve is closed.

Applies to: Vitocrossal 300 CA3B Dual Fuel 2.5 to 6.0

Common causes of Viessmann code F E1

  • First gas valve seat leaking or GDW2 fault
  • Gas pressure switch 2 activated while the burner test firing valve is closed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F E1

Show all 41 models

2.53.04.05.06.0CA3B 2.5CA3B 3.0CA3B 3.5CA3B 4.0CA3B 5.0CA3B 6.0CA3B Dual Fuel 2.5CA3B Dual Fuel 2.5 BoilerCA3B Dual Fuel 3.0CA3B Dual Fuel 3.0 BoilerCA3B Dual Fuel 3.5CA3B Dual Fuel 3.5 BoilerCA3B Dual Fuel 4.0CA3B Dual Fuel 4.0 BoilerCA3B Dual Fuel 5.0CA3B Dual Fuel 5.0 BoilerCA3B Dual Fuel 6.0CA3B Dual Fuel 6.0 BoilerCA3B Dual Fuel Series 2.5CA3B Dual Fuel Series 3.0CA3B Dual Fuel Series 3.5CA3B Dual Fuel Series 4.0CA3B Dual Fuel Series 5.0CA3B Dual Fuel Series 6.0Vitocrossal 300 CA3B Dual Fuel 2.5Vitocrossal 300 CA3B Dual Fuel 3.0Vitocrossal 300 CA3B Dual Fuel 3.5Vitocrossal 300 CA3B Dual Fuel 4.0Vitocrossal 300 CA3B Dual Fuel 5.0Vitocrossal 300 CA3B Dual Fuel 6.0Vitocrossal 300 CA3B Dual Fuel Series 2.5Vitocrossal 300 CA3B Dual Fuel Series 3.0Vitocrossal 300 CA3B Dual Fuel Series 3.5Vitocrossal 300 CA3B Dual Fuel Series 4.0Vitocrossal 300 CA3B Dual Fuel Series 5.0Vitocrossal 300 CA3B Dual Fuel Series 6.0

Other Viessmann Boiler codes

CodeMeaning
FDFault, combustion control unit
FD (unnamed row)Burner control unit fault (EMC)
F d0Multiple gas types selected
FD 227Boiler coding card missing (with B7)
FECoding plug defective or wrong EMV error
F E0Gas inlet valve not tight (dual fuel)
F E2Gas pressure switch 2 (GDW2) did not close or gas shortage / valve leak
F E4Repeated undervoltage, burner shuts down
F E5Internal burner control fault, ionization input
F E7Boiler temperature sensor 2 short circuit
F E8Boiler temperature sensor 2 drift
F E9Boiler temperature sensor 2 lead break

All Viessmann Boiler error codes →

Viessmann code F E1: homeowner questions

What does Viessmann code F E1 mean?

Gas pressure switch 2 (GDW2) closed on pressure rise. Gas pressure switch 2 activates while the burner test firing valve is closed.

Is it safe to keep using my boiler with code F E1?

No. Code F E1 is a safety shutdown, so keep the boiler off until a licensed technician has checked it.

Can I reset Viessmann code F E1 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Viessmann code F E1 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 300 CA3B Dual Fuel service instructions, p. 28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.