Viessmann 311 Error Codes
Viessmann 311 error codes and diagnostic codes (also listed as Vitocrossal 200 CM2 311). The 311 is a Viessmann boiler in the Vitocrossal 200 CM2 series.
Viessmann 311 error codes list
Troubleshooting the 311
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
- Won't fire All brands · Boiler
- Access the burner and disconnect the burner control Viessmann · Boiler
- Acknowledged fault comes back Viessmann · Boiler
- Altitude derating Viessmann · Boiler
- Annual heating contractor service Viessmann · Boiler
- Boiler exposed to water Viessmann · Boiler
- Boiler location restrictions Viessmann · Boiler
- Boiler room location and air quality Viessmann · Boiler
- Burner control display layout and exit Viessmann · Boiler
- Burner service: start-up after work Viessmann · Boiler
- Change altitude setting on burner control Viessmann · Boiler
- Change gas type on burner control Viessmann · Boiler
- Check and adjust CO2 at lower heating output Viessmann · Boiler
- Check and adjust CO2 at upper heating input Viessmann · Boiler
- Check condensate drain and neutralizing unit Viessmann · Boiler
- Check cylinder burner assembly Viessmann · Boiler
- Check expansion tank and system pressure Viessmann · Boiler
- Check flue side gaskets and seals Viessmann · Boiler
- Check gas connections for leaks Viessmann · Boiler
- Check gaskets, seals and insulation Viessmann · Boiler
- Check ignition and ionization electrodes Viessmann · Boiler
- Checking CO2 level at upper heating input Viessmann · Boiler
- Checking static and supply pressure Viessmann · Boiler
- Clean combustion chamber and heat exchanger Viessmann · Boiler
- Clean the burner and venturi Viessmann · Boiler
- Clear the fault memory Viessmann · Boiler
- CO formed or burner very sooty (no fault display) Viessmann · Boiler
- CO2 content too low (no fault display) Viessmann · Boiler
- Combustion air and carbon monoxide precautions Viessmann · Boiler
- Combustion fault through pulsation (no fault display) Viessmann · Boiler
- Commissioning hand-over checklist Viessmann · Boiler
- Condensate and venting notes Viessmann · Boiler
- Condensate disposal Viessmann · Boiler
- Condensate not draining, burner shuts down Viessmann · Boiler
- Conversion to liquid propane gas (LPG) Viessmann · Boiler
- Conversion to natural gas (NG) Viessmann · Boiler
- Deleting the hours run meter Viessmann · Boiler
- Do not adjust the valve seat gas pressure switch GDW2 Viessmann · Boiler
- Domestic hot water via indirect cylinder Viessmann · Boiler
- Enter CO2 test mode (relay test and modulation) Viessmann · Boiler
- Enter emissions test mode Viessmann · Boiler
- Entering the information and configuration menu Viessmann · Boiler
- Excessive flue gas temperature (no fault display) Viessmann · Boiler
- Filling the condensate siphon Viessmann · Boiler
- Fixed high limit test (RTD sensors) Viessmann · Boiler
- Flame goes out during operation (no fault display) Viessmann · Boiler
- Flue gas odour Viessmann · Boiler
- Freeze protection when the system is drained Viessmann · Boiler
- Freezing protection when the home is left unattended Viessmann · Boiler
- Front panel indicators and switches Viessmann · Boiler
- Gas odour in the boiler room Viessmann · Boiler
- Gas smell emergency Viessmann · Boiler
- Inlet damper must be fully open Viessmann · Boiler
- Install auxiliary low gas pressure switch Viessmann · Boiler
- Isolate the boiler before any work Viessmann · Boiler
- Keep leak spray away from electrical contacts Viessmann · Boiler
- Lag boilers lose contact with lead boiler (cascade) Viessmann · Boiler
- Leak test after gas work Viessmann · Boiler
- Long shutdown cleaning Viessmann · Boiler
- Overheating or gas supply fails to shut off Viessmann · Boiler
- Parameter R62 after a flame loss Viessmann · Boiler
- Periodic heating contractor checks Viessmann · Boiler
- Preparing to work on the system Viessmann · Boiler
- Protect electronics from static discharge Viessmann · Boiler
- Read ionization current through the burner control Viessmann · Boiler
- Read the fault memory Viessmann · Boiler
- Reduce operational input on burner control Viessmann · Boiler
- Replace 2/2-way solenoid valve (choke valve) Viessmann · Boiler
- Replace air pressure switch Viessmann · Boiler
- Replace boiler water temperature sensor Viessmann · Boiler
- Replace burner control coding card Viessmann · Boiler
- Replace burner control programming unit Viessmann · Boiler
- Replace burner control sub-base Viessmann · Boiler
- Replace burner door Viessmann · Boiler
- Replace burner fan Viessmann · Boiler
- Replace burner tube Viessmann · Boiler
- Replace gas valve (LPG) Viessmann · Boiler
- Replace gas valve (natural gas) Viessmann · Boiler
- Replace ignition electrode block Viessmann · Boiler
- Replace ignition unit and ignition cables Viessmann · Boiler
- Replace inlet damper linkage Viessmann · Boiler
- Replace inlet damper servomotor Viessmann · Boiler
- Replace ionization electrode block Viessmann · Boiler
- Replace motorized burner inlet damper Viessmann · Boiler
- Replace plug console with relay Viessmann · Boiler
- Replace the boiler temperature sensor Viessmann · Boiler
- Replacing the burner door Viessmann · Boiler
- Replacing the burner door refractory Viessmann · Boiler
- Reset after auxiliary low gas pressure switch fault Viessmann · Boiler
- Reset the burner control unit after a fault Viessmann · Boiler
- Resetting operating parameters to factory settings Viessmann · Boiler
- Service interval reminders Viessmann · Boiler
- Setting the maximum operational burner input Viessmann · Boiler
- Setting the motorized flue damper (flue gas cascade) Viessmann · Boiler
- Shut down the boiler for service Viessmann · Boiler
- Smell of flue gas Viessmann · Boiler
- Tools and literature to have on site Viessmann · Boiler
- Torque boiler door screws Viessmann · Boiler
- Use only Viessmann replacement parts Viessmann · Boiler
- Viewing ionization current Viessmann · Boiler
- Water quality and hard water Viessmann · Boiler
All Viessmann Boiler error codes →
Homeowner help: Boiler Not Heating: What to Check
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.