Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code F F9: Fan speed or feedback fault (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F F9 on a boiler means: Fan speed or feedback fault. It is also called Viessmann diagnostic code F F9.

High severityBoilerVitocrossal 200 CM2

Homeowner? What Viessmann code F F9 means for you

Call a technician Your boiler is reporting: Fan speed or feedback fault. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F F9 mean?

Fan not running, fan speed not reached, fan speed varies, or no fan feedback.

Applies to: Vitocrossal 200 CM2 burner control unit

Common causes of Viessmann code F F9

  • Fan faulty
  • Cables faulty or broken, including cable a-OA
  • Internal fault: fan cannot reach set value

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F F9

186246311CM2 186 burnerCM2 246 burnerCM2 311 burnerVitocrossal 200 CM2 186Vitocrossal 200 CM2 246Vitocrossal 200 CM2 311Vitocrossal 200 CM2 400Vitocrossal 200 CM2 500Vitocrossal 200 CM2 620Vitocrossal 200 CM2 620 TX

Other Viessmann Boiler codes

CodeMeaning
F F3Faulty flame signal at start-up or after post-purge
F F4No flame during safety time
F F5Air pressure switch 1 fault
F F6No gas pressure at gas pressure switch
F F7Air pressure switch 1 idle-state check fault
F F8Flame goes out during operation
FF 224Internal fault or reset button blocked
F FAFan runs without demand
F FbCombustion chamber pressure too high, burner not starting
F FdFault around burner control unit (internal or EMC)
F FFFault around burner control unit (internal or EMC)
First select button 1, 2 or 3Select heating circuit first

All Viessmann Boiler error codes →

Viessmann code F F9: homeowner questions

What does Viessmann code F F9 mean?

Fan speed or feedback fault. Fan not running, fan speed not reached, fan speed varies, or no fan feedback.

Is it safe to keep using my boiler with code F F9?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code F F9 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F F9 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F F9 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CM2 186 to 311 Service Instructions, p. 52-53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977