Updated · by Aurora Star Tech Inc.

Viessmann error code F.519 on a boiler means: BACnet communication error with building management system. It is also called Viessmann diagnostic code F.519.

Low severityBoilerVitocrossal 200 CI2

Homeowner? What Viessmann code F.519 means for you

Usually minor Your boiler is reporting: BACnet communication error with building management system. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.519 mean?

Building management system communication is not possible, so external control is not possible. The boiler returns to internal control target values.

Applies to: Vitocrossal 200 CI2 boiler with BACnet

Common causes of Viessmann code F.519

  • Communication error BACnet
  • Same device ID used twice in the same network
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.519

Show all 21 models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

Other Viessmann Boiler codes

CodeMeaning
F.468Ionization current too high during calibration
F.471Sensor circuit fault (call for heat)
F.473HMU communication error
F.474Program run monitoring error
F.477Solar differential temperature monitoring
F.517Remote control not working
F.520Modbus communication error with building management system
F.527Wrong HMU parameter set
F.528Wrong BCU parameter set
F.530Solar sensor missing or open
F.538System return sensor open (SDIO)
F.540Condensate back-up in heat cell

All Viessmann Boiler error codes →

Viessmann code F.519: homeowner questions

What does Viessmann code F.519 mean?

BACnet communication error with building management system. Building management system communication is not possible, so external control is not possible. The boiler returns to internal control target values.

Is it safe to keep using my boiler with code F.519?

Usually yes. Code F.519 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code F.519 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F.519 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F.519 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CI2 service instructions, p. 66. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.