Viessmann Error Code B8 141: Flue gas sensor cable broken (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code B8 141 on a boiler means: Flue gas sensor cable broken. It is also called Viessmann diagnostic code B8 141.

High severityBoilerVitodens 200-W B2HA

Homeowner? What Viessmann code B8 141 means for you

Call a technician Your boiler is reporting: Flue gas sensor cable broken. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code B8 141 mean?

Burner blocked. Flue gas temperature sensor cable is broken. Detailed code 141.

Applies to: Vitodens 200-W B2HA 45, 60

Common causes of Viessmann code B8 141

  • Flue gas temperature sensor cable broken
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
b1Communication fault, programming unit (internal)
b4Internal fault
b5Internal fault
b6Internal fault, invalid hardware recognition
b7Internal fault, boiler protection coding card
b8Interruption, flue gas temperature sensor
b9Failure plausibility test
bAFault, mixing valve module (KM-BUS)
BBCommunication error, heating circuit 3 mixing valve kit
b b1Programming unit communication fault
b b4Undefined control characteristics: internal electronics fault
b b5Control mode fault (cause and remedy not legible)

All Viessmann Boiler error codes →

Viessmann code B8 141: homeowner questions

What does Viessmann code B8 141 mean?

Flue gas sensor cable broken. Burner blocked. Flue gas temperature sensor cable is broken. Detailed code 141.

Is it safe to keep using my boiler with code B8 141?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code B8 141 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code B8 141 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code B8 141 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 72. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.