Viessmann Error Code BB: Communication error, heating circuit 3 mixing valve kit (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code BB on a boiler means: Communication error, heating circuit 3 mixing valve kit. It is also called Viessmann diagnostic code BB.

Medium severityBoilerVitocrossal 300

Homeowner? What Viessmann code BB means for you

Check, then call Your boiler is reporting: Communication error, heating circuit 3 mixing valve kit. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code BB mean?

Mixing valve regulates to a supply temperature of 68 F (20 C).

Applies to: Heating circuit 3 extension kit

Common causes of Viessmann code BB

  • Communication error, extension kit for heating circuit 3 with mixing valve
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code BB

2635455794125160199CU3ACU3A 26CU3A 35CU3A 45CU3A 57CU3A 94CU3A 125CU3A 160CU3A 199Vitocrossal 300, type CT3

Other Viessmann Boiler codes

CodeMeaning
b6Internal fault, invalid hardware recognition
b7Internal fault, boiler protection coding card
b8Interruption, flue gas temperature sensor
B8 141Flue gas sensor cable broken
b9Failure plausibility test
bAFault, mixing valve module (KM-BUS)
b b1Programming unit communication fault
b b4Undefined control characteristics: internal electronics fault
b b5Control mode fault (cause and remedy not legible)
b b6Undefined control characteristics: invalid hardware recognized
b bcRemote control (Vitotrol) communication fault
b bdRemote control DIP switch incorrectly set

All Viessmann Boiler error codes →

Viessmann code BB: homeowner questions

What does Viessmann code BB mean?

Communication error, heating circuit 3 mixing valve kit. Mixing valve regulates to a supply temperature of 68 F (20 C).

Is it safe to keep using my boiler with code BB?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code BB myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code BB comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code BB near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitocrossal 300 CU3A 26 to 199 Service Instructions, p. 87. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977