Viessmann Error Code F.882: Gas outlet pressure too high (GDW3) (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F.882 on a boiler means: Gas outlet pressure too high (GDW3). It is also called Viessmann diagnostic code F.882.

Critical severityBoilerVitocrossal 200 CI2

Homeowner? What Viessmann code F.882 means for you

Stop and call Your boiler is reporting: Gas outlet pressure too high (GDW3). This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.882 mean?

Burner or system is in a fault state because the gas outlet pressure at GDW3 is too high.

Applies to: Vitocrossal 200 CI2 boiler

Common causes of Viessmann code F.882

  • Gas outlet pressure too high (GDW3)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.882

Show all 21 models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

Other Viessmann Boiler codes

CodeMeaning
F.694Fault in heat generator supply temperature sensor
F.762System pressure too low
F.763Gas pressure too high
F.764Lag boiler reports a fault
F.765Lead boiler communication error
F.875Communication error with lead boiler
F.883Gas valve test malfunction
F.884Gas valve test malfunction, VPS pressure not rising during filling
F.885Gas valve test faulty, valve seat V2 faulty
F.886Gas valve test malfunction, VPS pressure not dropping during VPS test
F.887Gas valve test faulty, valve seat V1 faulty
F.888Communication error with Lambda probe controller

All Viessmann Boiler error codes →

Viessmann code F.882: homeowner questions

What does Viessmann code F.882 mean?

Gas outlet pressure too high (GDW3). Burner or system is in a fault state because the gas outlet pressure at GDW3 is too high.

Is it safe to keep using my boiler with code F.882?

No. Code F.882 is a safety shutdown, so keep the boiler off until a licensed technician has checked it.

Can I reset Viessmann code F.882 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Viessmann code F.882 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CI2 service instructions, p. 70. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.