Updated · by Aurora Star Tech Inc.

Viessmann error code F.541 on a boiler means: No feedback from flue gas damper. It is also called Viessmann diagnostic code F.541.

High severityBoilerVitocrossal 200 CI2

Homeowner? What Viessmann code F.541 means for you

Call a technician Your boiler is reporting: No feedback from flue gas damper. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.541 mean?

Burner is in a fault state and the fan is in ventilation mode because the flue gas damper is closed or gives no feedback.

Applies to: Vitocrossal 200 CI2 boiler

Common causes of Viessmann code F.541

  • No feedback: flue gas damper closed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.541

Show all 21 models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

Other Viessmann Boiler codes

CodeMeaning
F.520Modbus communication error with building management system
F.527Wrong HMU parameter set
F.528Wrong BCU parameter set
F.530Solar sensor missing or open
F.538System return sensor open (SDIO)
F.540Condensate back-up in heat cell
F.542Heating circuit 1 supply sensor lead break, emergency mode
F.543Heating circuit 1 supply sensor short circuit, emergency mode
F.544HC2 mixed supply sensor open circuit
F.545HC2 mixed supply sensor short circuit
F.546HC3 mixed supply sensor open circuit
F.547HC3 mixed supply sensor short circuit

All Viessmann Boiler error codes →

Viessmann code F.541: homeowner questions

What does Viessmann code F.541 mean?

No feedback from flue gas damper. Burner is in a fault state and the fan is in ventilation mode because the flue gas damper is closed or gives no feedback.

Is it safe to keep using my boiler with code F.541?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code F.541 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F.541 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F.541 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CI2 service instructions, p. 67. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.