Viessmann Error Code A.48: Reduced system output: condensate backup or wind influence (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code A.48 on a boiler means: Reduced system output: condensate backup or wind influence. It is also called Viessmann diagnostic code A.48.

Low severityBoilerVitocrossal 200 CI2

Homeowner? What Viessmann code A.48 means for you

Usually minor Your boiler is reporting: Reduced system output: condensate backup or wind influence. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code A.48 mean?

Warning that the system output is reduced because of condensate backup or wind influence on the flue system.

Applies to: Vitocrossal 200 CI2

Common causes of Viessmann code A.48

  • Condensate backup
  • Wind influence from non-approved flue systems or wall terminals
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code A.48

Show all 21 models

399500750100015002000CI2 399CI2 399/500CI2 500CI2 750CI2 750/1000CI2 1000CI2 1500CI2 1500/2000CI2 2000Vitocrossal 200 CI2 399Vitocrossal 200 CI2 500Vitocrossal 200 CI2 750Vitocrossal 200 CI2 1000Vitocrossal 200 CI2 1500Vitocrossal 200 CI2 2000

Other Viessmann Boiler codes

CodeMeaning
63572 hBurner hours run, 1st stage
AAUX demand active indicator
A.12Real-time clock battery flat
A.18Possible condensate back-up in heat cell
A.19Temperature limiter has responded
A.20Service interval could not be activated
A0Fault/failure module 2, safety device input 1
A1Fault/failure module 2, safety device input 2
A2Fault/failure module 2, safety device input 3
A3Fault/failure module 2, safety device input 4
A4Fault/failure module 2, external
A7Wireless clock module fault

All Viessmann Boiler error codes →

Viessmann code A.48: homeowner questions

What does Viessmann code A.48 mean?

Reduced system output: condensate backup or wind influence. Warning that the system output is reduced because of condensate backup or wind influence on the flue system.

Is it safe to keep using my boiler with code A.48?

Usually yes. Code A.48 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code A.48 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code A.48 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code A.48 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 200 CI2 Service Instructions, p. 75. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977