Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code 00572.h: Burner hours run, 2nd stage (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 00572.h on a boiler means: Burner hours run, 2nd stage. It is also called Viessmann diagnostic code 00572.h.

Low severityBoilerVitotronic 100, GC1

Homeowner? What Viessmann code 00572.h means for you

Usually minor Your boiler is reporting: Burner hours run, 2nd stage. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 00572.h mean?

Approximate burner run hours for the second stage. Can be reset to 0 with the D button.

Applies to: Vitotronic 100, GC1 scan display

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
92Solar collector temperature short circuit
93Solar collector return temperature short circuit
94Solar collector DHW tank temperature sensor short circuit
98Open circuit, Solarmodule sensor 3 (SM1 sensor 7)
98 and 99Fault at Vitocom 200/300 or Vitogate 200
99Open circuit, Solarmodule sensor 4 (SM1 sensor 10)
03572.hBurner hours run, 1st stage
09572 hBurner hours run, 2nd stage
30417Burner starts
30417.Burner starts
35510Maintenance: burner run hours reached
35510 hService message: burner hours reached

All Viessmann Boiler error codes →

Viessmann code 00572.h: homeowner questions

What does Viessmann code 00572.h mean?

Burner hours run, 2nd stage. Approximate burner run hours for the second stage. Can be reset to 0 with the D button.

Is it safe to keep using my boiler with code 00572.h?

Usually yes. Code 00572.h is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code 00572.h myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 00572.h comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 00572.h near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocontrol-S VD2/CT3/CM2 operating instructions, p. 28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977