Viessmann Error Code 98: Open circuit, Solarmodule sensor 3 (SM1 sensor 7) (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code 98 on a boiler means: Open circuit, Solarmodule sensor 3 (SM1 sensor 7). It is also called Viessmann diagnostic code 98.

Medium severityBoilerVersatronik 300

Homeowner? What Viessmann code 98 means for you

Check, then call Your boiler is reporting: Open circuit, Solarmodule sensor 3 (SM1 sensor 7). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code 98 mean?

Solar module sensor 3 circuit is open.

Applies to: Versatronik 300 cascade control

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
89Open circuit, burner control flue gas temperature limit sensor
90Short circuit, Solarmodule sensor 3 (SM1 sensor 7)
91Short circuit, Solarmodule sensor 4 (SM1 sensor 10)
92Solar collector temperature short circuit
93Solar collector return temperature short circuit
94Solar collector DHW tank temperature sensor short circuit
98 and 99Fault at Vitocom 200/300 or Vitogate 200
99Open circuit, Solarmodule sensor 4 (SM1 sensor 10)
00572.hBurner hours run, 2nd stage
03572.hBurner hours run, 1st stage
09572 hBurner hours run, 2nd stage
30417Burner starts

All Viessmann Boiler error codes →

Viessmann code 98: homeowner questions

What does Viessmann code 98 mean?

Open circuit, Solarmodule sensor 3 (SM1 sensor 7). Solar module sensor 3 circuit is open.

Is it safe to keep using my boiler with code 98?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code 98 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code 98 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code 98 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 300 Cascade Control manual, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.