Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code FD: Fault, combustion control unit (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code FD on a boiler means: Fault, combustion control unit. It is also called Viessmann diagnostic code FD.

High severityBoilerVersatronik 585

Homeowner? What Viessmann code FD means for you

Call a technician Your boiler is reporting: Fault, combustion control unit. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code FD mean?

General fault in the combustion control unit. Gateway value 253 (dec).

Applies to: Viessmann Vitotronic controls via Versatronik 585 gateway

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code FD

Versatronik 585 VI/BACIP

Other Viessmann Boiler codes

CodeMeaning
FA 154Fan not at standstill
FaultFault indicator flashing (fault search)
FbCombustion chamber pressure too high
F b7Coding card missing, incorrect or not matching
FCControl of modulation valve defective
FC 190Gas valve or modulation valve control fault, or vent blocked
FD (unnamed row)Burner control unit fault (EMC)
F d0Multiple gas types selected
FD 227Boiler coding card missing (with B7)
FECoding plug defective or wrong EMV error
F E0Gas inlet valve not tight (dual fuel)
F E1Gas pressure switch 2 (GDW2) closed on pressure rise

All Viessmann Boiler error codes →

Viessmann code FD: homeowner questions

What does Viessmann code FD mean?

Fault, combustion control unit. General fault in the combustion control unit. Gateway value 253 (dec).

Is it safe to keep using my boiler with code FD?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code FD myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code FD comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code FD near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 585 BACnetIP manual, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977