Viessmann Error Code S.154-1: Boiler internal flowswitch open (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code S.154-1 on a boiler means: Boiler internal flowswitch open. It is also called Viessmann diagnostic code S.154-1.

Low severityBoilerVitodens 100-W B1HE · Vitodens 100-W B1KE

Homeowner? What Viessmann code S.154-1 means for you

Usually minor Your boiler is reporting: Boiler internal flowswitch open. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code S.154-1 mean?

The boiler internal flowswitch is in the open position.

Applies to: Boiler internal flowswitch

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
S.74Heating suppression
S.75DHW recirculation pump active
S.94No demand, external hook-up HC1
S.95No demand, external hook-up HC2
S.96No demand, external hook-up HC3
S.154Internal flow switch open
SERVSERV shown in display during service mode
ServiceService due
Slab curingSlab curing function active
UWaiting for restart
Without functionButton has no function
___12Maintenance: time interval reached

All Viessmann Boiler error codes →

Viessmann code S.154-1: homeowner questions

What does Viessmann code S.154-1 mean?

Boiler internal flowswitch open. The boiler internal flowswitch is in the open position.

Is it safe to keep using my boiler with code S.154-1?

Usually yes. Code S.154-1 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code S.154-1 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code S.154-1 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code S.154-1 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 70. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977