Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code LED 1s ON / 3s OFF: Coco OT no CAN communication (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code LED 1s ON / 3s OFF on a boiler means: Coco OT no CAN communication. It is also called Viessmann diagnostic code LED 1s ON / 3s OFF.

High severityBoilerVersatronik 200

Homeowner? What Viessmann code LED 1s ON / 3s OFF means for you

Call a technician Your boiler is reporting: Coco OT no CAN communication. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code LED 1s ON / 3s OFF mean?

The LED flashes 1 second on and 3 seconds off, which means there is no CAN communication.

Applies to: Coco OT module LED indicator

Common causes of Viessmann code LED 1s ON / 3s OFF

  • Problem on the CAN link between the Versatronik 200 and the Coco OT.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
HOHoliday operation
iStand-by operating mode
I.56External demand active
I.57External blocking active
I.59Parameters restored
jService operation
LED 3s ON / 1s OFFCoco OT no OT communication
LED OFFCoco OT LED off, no BUS communication
LED ONCoco OT LED on, communication good
MServiceService call required
N/A 2Hold: no or low gas pressure
N/A 3Hold: no boiler water circulation

All Viessmann Boiler error codes →

Viessmann code LED 1s ON / 3s OFF: homeowner questions

What does Viessmann code LED 1s ON / 3s OFF mean?

Coco OT no CAN communication. The LED flashes 1 second on and 3 seconds off, which means there is no CAN communication.

Is it safe to keep using my boiler with code LED 1s ON / 3s OFF?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code LED 1s ON / 3s OFF myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code LED 1s ON / 3s OFF comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code LED 1s ON / 3s OFF near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 200 installation and operating manual, p. 19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977