Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code F 89: Secondary boiler water temperature sensor lead break (A or B) (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F 89 on a boiler means: Secondary boiler water temperature sensor lead break (A or B). It is also called Viessmann diagnostic code F 89.

Medium severityBoilerVitocrossal 300 CA3B Dual Fuel

Homeowner? What Viessmann code F 89 means for you

Check, then call Your boiler is reporting: Secondary boiler water temperature sensor lead break (A or B). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F 89 mean?

Burner control unit enters fault state.

Applies to: Vitocrossal 300 CA3B Dual Fuel 2.5 to 6.0

Common causes of Viessmann code F 89

  • Lead break in secondary boiler water temperature sensor (A or B) or burner control unit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F 89

Show all 41 models

2.53.04.05.06.0CA3B 2.5CA3B 3.0CA3B 3.5CA3B 4.0CA3B 5.0CA3B 6.0CA3B Dual Fuel 2.5CA3B Dual Fuel 2.5 BoilerCA3B Dual Fuel 3.0CA3B Dual Fuel 3.0 BoilerCA3B Dual Fuel 3.5CA3B Dual Fuel 3.5 BoilerCA3B Dual Fuel 4.0CA3B Dual Fuel 4.0 BoilerCA3B Dual Fuel 5.0CA3B Dual Fuel 5.0 BoilerCA3B Dual Fuel 6.0CA3B Dual Fuel 6.0 BoilerCA3B Dual Fuel Series 2.5CA3B Dual Fuel Series 3.0CA3B Dual Fuel Series 3.5CA3B Dual Fuel Series 4.0CA3B Dual Fuel Series 5.0CA3B Dual Fuel Series 6.0Vitocrossal 300 CA3B Dual Fuel 2.5Vitocrossal 300 CA3B Dual Fuel 3.0Vitocrossal 300 CA3B Dual Fuel 3.5Vitocrossal 300 CA3B Dual Fuel 4.0Vitocrossal 300 CA3B Dual Fuel 5.0Vitocrossal 300 CA3B Dual Fuel 6.0Vitocrossal 300 CA3B Dual Fuel Series 2.5Vitocrossal 300 CA3B Dual Fuel Series 3.0Vitocrossal 300 CA3B Dual Fuel Series 3.5Vitocrossal 300 CA3B Dual Fuel Series 4.0Vitocrossal 300 CA3B Dual Fuel Series 5.0Vitocrossal 300 CA3B Dual Fuel Series 6.0

Other Viessmann Boiler codes

CodeMeaning
F9 151 or 152Fan speed too low at burner start
F 80Boiler water temperature sensor short circuit
F 81Boiler water temperature sensor drift
F 82Secondary boiler water temperature sensor short circuit (A or B)
F 83Secondary boiler water temperature sensor drift (A or B)
F 88Boiler water temperature sensor lead break
FABlower speed too high at burner start
FA 154Fan not at standstill
FaultFault indicator flashing (fault search)
FbCombustion chamber pressure too high
F b7Coding card missing, incorrect or not matching
FCControl of modulation valve defective

All Viessmann Boiler error codes →

Viessmann code F 89: homeowner questions

What does Viessmann code F 89 mean?

Secondary boiler water temperature sensor lead break (A or B). Burner control unit enters fault state.

Is it safe to keep using my boiler with code F 89?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code F 89 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F 89 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F 89 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitocrossal 300 CA3B Dual Fuel service instructions, p. 28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977