Viessmann Error Code Check not OK: Participant check failed (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code Check not OK on a boiler means: Participant check failed. It is also called Viessmann diagnostic code Check not OK.

Medium severityBoilerVitotronic 300-K MW1S

Homeowner? What Viessmann code Check not OK means for you

Check, then call Your boiler is reporting: Participant check failed. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code Check not OK mean?

Shown when communication is not established with the selected participant.

Applies to: Vitotronic 300-K, MW1S

Common causes of Viessmann code Check not OK

  • Communication not established with the selected device
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
c cfLON communication module fault
CdCommunication fault, Vitocom 300 (KM-BUS)
CECommunication fault, fault indicator module (KM-BUS)
cEePlug-in adaptor for external safety equipment communication error
Centralized operationCentralized operation active
CFCommunication fault: wrong LON module
Check OKParticipant check OK
Connection errorDisplay link lost to HMU
DFactory settings active
d1Burner fault, boiler
d2Fault module 2 communication failure
d3EA1 module communication failure

All Viessmann Boiler error codes →

Viessmann code Check not OK: homeowner questions

What does Viessmann code Check not OK mean?

Participant check failed. Shown when communication is not established with the selected participant.

Is it safe to keep using my boiler with code Check not OK?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code Check not OK myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code Check not OK comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code Check not OK near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitotronic 100/300-K installation and service manual, p. 76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977