Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code bF: Compatibility failure LON module (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code bF on a boiler means: Compatibility failure LON module. It is also called Viessmann diagnostic code bF.

High severityBoilerVersatronik 300

Homeowner? What Viessmann code bF means for you

Call a technician Your boiler is reporting: Compatibility failure LON module. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code bF mean?

LON module is not compatible.

Applies to: Versatronik 300 cascade control

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
b bdRemote control DIP switch incorrectly set
b beRemote control DIP switch incorrectly set (second entry)
b bfIncorrect LON communication module
bCFault, Vitotrol heating circuit 1 (KM-BUS)
bdFault, Vitotrol heating circuit 2 (KM-BUS)
bEFault, Vitotrol heating circuit 3 (KM-BUS)
Burner faultBurner locked out
C24 hour reduced heating operation
C1External fault indication, boiler
C2Communication fault solar control unit (KM-BUS)
C3Communication failure AM1 module
C40-10 V module communication failure

All Viessmann Boiler error codes →

Viessmann code bF: homeowner questions

What does Viessmann code bF mean?

Compatibility failure LON module. LON module is not compatible.

Is it safe to keep using my boiler with code bF?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code bF myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code bF comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code bF near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik 300 Cascade Control manual, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair